Abstract

Abstract An overview is given on work by the author's group on integrated optical (IO) sensors. The sensors make use of guided waves or modes in optical waveguides, in particular of the orthogonally polarized TE 0 and TM 0 modes in very thin planar waveguides of high refractive index. The principle of all direct (bio)chemical waveguide or IO sensors is as follows. A chemically selective coating on the waveguide surface binds the analyte molecules contained in the gaseous or liquid sample. Thus, the refractive index of the medium near the waveguide surface (more precisely, within the penetration depth Δz of the evanescent field of the guided wave) is changed. This effect in turn induces changes ΔN TE 0 and ΔN TM 0 of the effective refractive indices N TE 0 and N TM 0 of the guided modes. for example, in biochemical affinity sensors the chemically selective coating contains receptor molecules that specifically or selectively bind certain ligands as analyte molecules; in particular, in immunosensors or immunoassays the receptors are antibodies (or antigens, respectively) and the analyte molecules are the corresponding antigens (or antibodies). These ‘direct’ affinity of immunosensors eliminate the use of (e.g., fluorescently) labelled reagents. Effective refractive-index changes ΔN can also be induced by two other effects; namely by unspecific adsorption of molecules on the (uncoated) waveguide surface (or in pores of a waveguiding film F itself if it is microporous) and by refractive-index changes Δn C of the liquid sample. In the latter case the IO sensors work as refractometers. The effective refractive indices N give the phase velocity ν ph = c / N of the guided modes, where c is the velocity of light in vacuum. This means that the effective refractive-index changes ΔN can be measured by various optical means. Consequently, a number of different types of IO sensors can be used, in particular, grating couplers and interferometers. In the paper, I report on our own work on IO sensors including: the discovery of the basic sensor effect with grating couplers as sensors for relative-humidity changes, the theory of the sensor sensitivities, and experimental results obtained with three different types of IO sensors developed in our laboratory, namely input grating couplers, output grating couplers and the difference or polarimetric interferometer. The experiments have been performed with dip-coated SiO 2 TiO 2 waveguiding films of refractive index n F ≈ 1.75–1.88, on glass, silica and silicon wafers with oxidized buffer layers as substrates. The sensors working as refractometers are tested, for example, with glucose solutions of different concentrations. The adsorption of proteins (h-IgG, BSA, protein A, avidin) is monitored in real time. Not only the surface concentration Γ, with a resolution of a few pg mm −2 , but also the thickness d F′ and the refractive index n F′ of the adsorbing (mono)layers are determined as functions of time. Also immunoreactions (e.g., between h-IgG and anti-h-IgG, and between IgGs and protein A) and affinity reactions (between avidin and biotinylated proteins, such as biotin BSA) are observed in real time. The feasibility of IO immunosensors or affinity sensors or immunoassays with sub-nanomolar detection limits is demonstrated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.