Abstract

Forty-six patients with malfunctioning hemodialysis access fistulas were treated with balloon angioplasty. The initial percutaneous transluminal angioplasty procedure was successful in 16 (89%) of 18 patients with stenoses and in 13 (46%) of 28 with occlusions. In ten patients (seven with stenoses and three with occlusions) repeated dilation (two to five times; mean, two times) became necessary due to recurrent malfunction 1-24 months (mean, 6 months) after the first intervention. In the 16 patients with stenoses, the patency rate after 6 months was 93%; after 1 year, 91%; and after 2 years, 57%. In the 12 patients with occlusions, the rates were 80%, 50%, and 14%, respectively. Dilation of stenoses in malfunctioning hemodialysis fistulas is the procedure of choice. If hemodialysis shunts malfunction, immediate dilation of stenotic lesions should be performed to prevent occlusion.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.