Abstract

With the wide applications of post-tensioned concrete structures, the grouting conditions of tendon ducts are paid more attentions. In order to accurately assess the internal grouting quality of the grouted tendon ducts and certainly guarantee the lifetime of prestressed concrete structures Ground Penetrating Radar (GPR), which is a kind of nondestructive testing (NDT) method, has been applied to inspect and evaluate qualitatively and quantitatively on the grouting defects, respectively. A series of in-house tests were carried out for simulating the defects of tendon ducts by foams with different sizes. The results show that the GPR technic was one of the optimal methods for inspecting the internal grouting quality of grouted tendon ducts for post-tensioned concrete structures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.