Abstract

The design of the capacitor bank driven insert of the first 100 T non-destructive magnet is described. The coil is wound with 8 conductor layers, and is internally reinforced with the multiphase alloy MP35N/sup TM/ in combination with a Zylon/sup TM/ fiber/epoxy composite. The deformation of the conductor is limited by the high modulus reinforcements, therefore, the coil will operate in the elastic state after conditioning. This ensures long magnet life. The insert coil will be energized by a 2.3 MJ, 18 kV capacitor bank operating at 15 kV. The mechanical deformation, heating and the magnetic field reduction due to the eddy currents in the MP35N/sup TM/ reinforcement are analyzed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.