Abstract
A radiotracer technique has been used to study the removal of Hg(II) ions from aqueous solutions by synthesized and well-characterized hydrous ferric oxide (HFO) and hydrous tungsten oxide (HTO). Adsorptive concentration (10 −4–10 −8 mol dm −3), pH (ca 4.0–10.0) and temperatures (303–333 K) were examined for assessing optimal conditions for removal of these ions. The uptake of Hg(II) ions, fitted well with the Freundlich isotherm, increased with increasing temperature. No significant desorption took place in the present temperature range. The presence of other anions and cations affected the uptake of Hg(II) markedly. Irradiation of hydrous ferric oxide and tungsten oxide by using a 11.1 × 10 9 Bq (Ra–Be) neutron source having a neutron flux of 3.9 × 10 6 cm −2 s −1 with the associated γ-dose rate of 1.72 Gy h −1 did not influence the extent of adsorption of Hg(II) significantly.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.