Abstract
Abstract Industrial experiments have been performed on a down-fired pulverized-coal 300 MWe utility boiler with vent air valve opening of 100% and 40%. The gas temperature distribution along the primary air and coal mixture flow, gas temperature distribution in the furnace, and gas components such as O2, CO, CO2 and NOx in the near-wall region were measured for the first time. The influence of vent air valve opening on coal combustion in the furnace was determined. The results indicate that ignition of the primary air and pulverized-coal mixture is delayed. The position of the gas temperature peak is above the arches. Emission of NOx is up to 2101 mg/m3 (at 6% O2 dry) with vent valve opening of 40%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.