Abstract

The continuity of a steered vacuum arc with Al cathode and N2 flow at a pressure between 0.1 and 5 Pa is investigated. Two constant-current power supplies (60 V open-circuit voltage/30 V load voltage and 310 V/240 V) and a constant-voltage power supply with open-circuit voltage 550 V are used. The arc current is 30 A, the N2 flow rate is 20 ml/min, and the transverse magnetic field density at the cathode edge is 1.2 mT. The following results are obtained. (1) When the power supply with lower open-circuit and load voltages is used, a decrease in pressure causes the arc to lose sustainability. (2) When the power supply with high open-circuit and load voltages is used, the arc can continue even at lower pressure. (3) When the power supply with higher load voltage is used, abnormal discharge behind the magnet field guide-disk may occur at lower pressure. The above-mentioned influence of power supply on arc continuity is interpreted in terms of column fall and generation of a new cathode spot. © 1999 Scripta Technica, Electr Eng Jpn, 128(3): 9–15, 1999

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.