Abstract
To obtain the specific values of the flowrate measurement uncertainty using the ultrasonic Doppler velocity profile (UVP) method under disturbed flow conditions, experimental measurements were performed. To generate a disturbed flow, obstacle plates were installed upstream of the test section. To estimate which experimental parameter dominates the uncertainty, parametric examinations are conducted for the obstacle plate configuration, the distance between the obstacle plates and the measurement section, the incident angle of the ultrasonic beam, and the flowrate. The maximum deviation of the measured flowrate from the reference flowrate exceeds 2% when the flowrate is measured 8D downstream of the obstacle plate. At a distance of 25D downstream, the deviation is within the fundamental uncertainty level of the flowrate measurement using the UVP method. Because several uncertainty factors in this examination are cross-correlated with each other, the uncertainties of these factors are evaluated independently using analysis of variance (ANOVA). The total uncertainty is 7.98%, 1.97%, and 1.14% at 8D, 16D, and 25D, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.