Abstract

In order to elucidate optimum operational parameters, five series of experiments with bench scale “A/O and MBR (membrane biological reactor)” devices were carried out. The HRTs of each anoxic and oxic bioreactor were maintained for 2˜6 h and for 3˜6 h, respectively. The internal recycle ratios were also changed from 100% to 300% of the influent feeding rate by peristaltic pump. There were no recognizable differences in the values of BOD removal efficiency, being around 99%, in the series of experiments. The same was true for T–N removal efficiency, which ranged about 60%. The similarity of the serial experiments for each parameter indicates that the extraordinarily high concentration of microorganisms in the bioreactor, i.e. 10,000–15,000 mg/l, strongly controls the entire process regardless of any moderate changes of the operational parameters.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.