Abstract
Two different diameters of Pt/Al2O3 spherical catalysts (1 mm and 2 mm) for HTP 98% decomposition were tested to compare the catalytic activity and catalyst ageing. Comparable decomposition performance efficiencies were obtained during thruster-like tests in a catalytic decomposition setup, even though the 1-mm showed a better reactivity and temperature rising time, including in cold-start operation. However, a rapid physical degradation accompanied by pressure peaks observed throughout testing of the 1-mm catalyst led to damage of the catalyst and apparition of fines, causing partial clogging of the bed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.