Abstract

Biofiltration systems are a promising retrofit option for site-constrained urban areas due to the vertical arrangement of treatment stages that leads to a relatively compact footprint. Existing knowledge about the influence of their design and configuration on hydrological, stormwater pollutant removal and long-term performance is limited and this has been identified as a barrier to their widespread uptake. Long-term simulations of lined and unlined biofiltration systems in four contrasting UK climatic regimes were used to assess the influence of climate, ponding depth, biofilter to drainage area ratio and infiltration rate on hydrological performance. The results showed that local differences in climate have a significant impact on performance and that infiltration rates as low as 0·36 mm/h are not suitable for locations in the UK with high rainfall unless the biofilter to drainage area ratio is greater than 10%. However, with higher infiltration rates (72 mm/h) a biofilter occupying only 3% of the impermeable catchment area would be capable of infiltrating 97% of annual rainfall in central England. Preliminary results of adsorption and column tests to assess the effectiveness of media amendments, specifically zeolite and granular activated carbon, for dissolved copper and phosphate removal are presented in this paper.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.