In this paper, the influence of charging conditions on permeability of porous PTFE membranes is studied by constant voltage corona charging at room and elevated temperatures and by measuring the flow rate in water when porous PTFE electret films are used as a filter membrane. We found that charging field and charging temperature strongly affect the flow rate of water, but charging time does not influence the flow rate markedly. The structure of porous PTFE film, investigated by a scanning electron microscope, is important for understanding the influence of charging conditions on the membrane permeability. The increase of the ratio of the bulk charge density to the surface charge density of the porous electret films is performed by thermal treatment during charging. Such porous films may be employed as electret filter membranes with high efficiency to purify dielectric liquids.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.