Abstract

The paper is devoted to the study of impact of additional dielectric coatings placed on the surface of the electrodes on the operation of a high-voltage insulation system with air as insulating medium. The study mainly focused on measurement of partial discharges (PDs) with the use of acoustic emission method. Tests were conducted in various levels of chamber pressure. Applicable parameters of recorded signals were analyzed with the use of applications developed in the environment of MATLAB software. The results of analyses clearly show that presence of additional coatings has impact on signal parameters and thus indirectly on PDs. The use of coatings reduces the duration of a single pulse (event) and increases its amplitude. Furthermore, the influence of degradation of the coating caused by individual discharges on the values of the analyzed parameters was analyzed. The study has shown, however, that this effect is negligible.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.