Abstract

A precise and simple method for the determination of 234Th activity by Cerenkov counting is described. A calibrated natural uranium solution (having 234 m Pa and 238U in secular equilibrium) in 0.1 M HNO 3 is used to construct the calibration curve. Because 231Th (a β-emitting nuclide present in the decay chain of 235U) contribution to Cerenkov counting is experimentally proved to be negligible only in the case of low enriched uranium samples, simple calculations are needed to accomplish the activity determination.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.