Abstract

We studied the use of a new ke0 value (0.6 min(-1)) for the Marsh pharmacokinetic model for propofol. Speed of induction and side-effects produced were compared with three other target-controlled infusion systems. Eighty patients of ASA physical status 1-2 were studied in four groups in a prospective, randomised study. Median (IQR [range]) induction times were shorter with the Marsh model in effect-site control mode with a ke0 of either 0.6 min(-1) (81 (61-101 [49-302])s, p < 0.01), or 1.2 min(-1) (78 (68-208 [51-325])s, p < 0.05), than with the Marsh model in blood concentration control (132 (90-246 [57-435])). The Schnider model in effect-site control produced induction times that were longer (298 (282-398 [58-513])s) than those observed with the Marsh model in blood control (p < 0.05), or either effect-site control mode (p < 0.001). There were no differences in the magnitude of blood pressure changes or frequency of apnoea between groups.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.