Abstract

Indoor environmental quality (IEQ) in hospital operating rooms (ORs) constitutes a major challenge for the proper design and operation of an energy efficient hospital. A subjective assessment of the indoor environment along with a short monitoring campaign was performed during the audits of 18 ORs at nine major Hellenic hospitals. A total of 557 medical personnel participated in an occupational survey, providing data for a subjective assessment of IEQ in the audited ORs. The OR personnel reported work related health symptoms and an assessment of indoor conditions (thermal, visual and acoustical comfort, and air quality). Overall, personnel reported an average of 2.24 work-related symptoms each, and 67.2% of respondents reported at least one. Women suffer more health symptoms than men. Special dispositions, such as smoking and allergies, increase the number of reported symptoms for male and female personnel. Personnel that perceive satisfactory indoor comfort conditions (temperature, humidity, ventilation, light, and noise) average 1.18 symptoms per person, while for satisfactory indoor air quality the average complaints are 0.99. The perception of satisfactory IEQ (satisfactory comfort conditions and air quality) reduces the average number of health complaints to 0.64 symptoms per person and improves working conditions, even in a demanding OR environment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.