Abstract

This paper introduces an enhanced commutation method applied to the indirect matrix converter topology. It is based on the detection of the load current polarity so as to cancel the turn-on delay times of the load-side converter's switches. The proposed method allows the grid-side converter devices to commutate at zero current with larger time interval widths provided for this safe commutation. Moreover, it has been shown through experimental results, carried out on a laboratory prototype of the matrix converter, that a substantial improvement of line current total harmonic distortion is achieved.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.