Abstract
Copyright: © 2015 Shintani H. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. Fenton reaction produces OH radicals from hydrogen peroxide with the catalyst of Fe2+ or Cu+. The sterilization mechanism of hydrogen peroxide can be explained from OH radicals. If so using Fenton reaction, OH radical from hydrogen peroxide may increase and increased result of sterilization can be attained. Fe2+ was inoculated onto the sterilization pack and by contacting hydrogen peroxide with Fe2+, Fenton reaction occurred. Production of OH radicals from hydrogen peroxide was increased and increased sterility efficiency can be confirmed from the comparison of D value to the control. The D values of hydrogen peroxide with Fe2+ and without Fe2+ were 5 s and 30 s, respectively, indicating OH radical formed greater by Fenton reaction. In addition, we studied the production of OH radicals from the UV exposure at 254 nm to hydrogen peroxide. The result of D values was compared with UV254 nm exposure and without UV 254 nm exposure, the D value of the former was 1.7 s and the latter was 3.3 s, respectively, indicating UV exposure supplied increased OH radicals. Furthermore sterility efficiency of Fenton reaction and UV 254 nm exposure was compared. Fenton reaction was inferior to UV 254 nm exposure due to the greater D value. The former was 5-10 s and the latter was 1.7 s. However, this comparison has a problem that primary package was absence and presence. UV exposure was absence and Fenton reaction was presence. Primary package present an obstacle to penetrate OH radicals into the interior of BI. As a conclusion, Fenton reaction was not always inferior to UV 254 nm exposure.
Highlights
Fenton reaction produces OH radicals from hydrogen peroxide with the catalyst of Fe2+ or Cu+
Production of OH radicals from hydrogen peroxide was increased and increased sterility efficiency can be confirmed from the comparison of D value to the control
The D values of hydrogen peroxide with Fe2+ and without Fe2+ were 5 s and 30 s, respectively, indicating OH radical formed greater by Fenton reaction
Summary
Fenton reaction produces OH radicals from hydrogen peroxide with the catalyst of Fe2+ or Cu+. The sterilization mechanism of hydrogen peroxide can be explained from OH radicals. If so using Fenton reaction, OH radical from hydrogen peroxide may increase and increased result of sterilization can be attained. Fe2+ was inoculated onto the sterilization pack and by contacting hydrogen peroxide with Fe2+, Fenton reaction occurred.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.