Abstract

With the aim of improving the usefulness of a solar system in energy-saving, the thermal behavior of the domestic hot water system was investigated. The energy/continuity equations were developed to investigate the transient analysis of a solar hot water system in three climatic regions in Saudi Arabia (Najran, Jeddah and Riyadh). By using a water-filled solar system, the energy consumption of the boiler reduced by 12478, 13,289 and 13,896 kWhyear in Najran, Riyadh and Jeddah, respectively. With the addition of WO3, CeO2, Al2O3, Fe3O4, CuO and MWCNT nanoparticles, although the thermal conductivity increases (positive effect), but at the same time, the parameter of density × specific heat may be reduced (negative effect), hence using nanoparticles maybe not useful. In this study, it was found that increasing the conductivity has a greater effect and therefore for all nanoparticles, the collector heat gain increased. The best results were related to the collector equipped with MWCNT, so that this collector had more energy-saving than the water-based one by 9963 (for Najran), 10,000 (for Riyadh) and 10,379 kWh/year (for Jeddah).

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.