Abstract

The effects of high-intensity pulsed electric fields (HIPEF) on oxidative enzymes and color of fresh carrot juice were studied. A response surface methodology (RSM) was used to evaluate the effect of pulse polarity (mono or bipolar mode), pulse width (from 1 to 7 μs), and pulse frequency (from 50 to 250 Hz) on color and peroxidase (POD) inactivation of carrot juice treated by HIPEF. The total treatment time and the electric field strength were set at 1,000 μs and 35 kV/cm, respectively, at a temperature below 35°C. The physicochemical characteristics of carrot juice were measured. There was a linear relationship between electrical conductivity and temperature of the carrot juice. The results showed that HIPEF-treated carrot juice at 35 kV/cm for 1,000 μs applying 6 μs pulse width at 200 Hz in bipolar mode led to 73.0% inactivation of POD. The color coordinates did not change significantly. Therefore, HIPEF was effective in POD inactivation and carrot juice color preservation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.