Abstract

This paper is the second part of a study regarding the biomechanical behaviour of mandibular bone in the context of different periodontal splinting systems, occlusal forces and load distributions. Electric resistive tensometry method was used to measure the strains developed in mandibular bone replica. The tests were carried out on six mandibular acrylic models, each with 8 natural teeth. The experimental groups were defined corresponding to the bone condition and splint type: normal height bone; bone resorption without splint; bone resorption and wire-composite splint; bone resorption and polyethylene fiber-reinforced composite splint. Each sample was subjected to three similar loading cycles, the force being applied successively on four incisors, two central incisors and canines, and the specific deformation values were read for four loading forces: 30 N, 50 N, 100 N and 150 N. In case of bone loss, the bone deformations are up to 110%. Periodontal splinting redistribute forces, reducing incisors bone strains associated with a slight increase in canine bone strains.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.