Abstract

The aim of this in vitro study was to assess the feasibility of using high-frequency sonography to identify colorectal lymph nodes and to diagnose colorectal lymph node metastasis. In part 1 of this study, resected colorectal tissues from 13 patients with colorectal cancer were scanned in a water bath using B-mode sonography performed at high frequency (10 MHz) to identify lymph nodes. The colorectal tissues were then carefully dissected to remove all lymph nodes. Detectability was calculated as the ratio of the number of sonographically detected nodes to the total number of histopathologically confirmed nodes. Student's t test was performed to compare sizes between these groups; a p value of less than 0.05 was considered significant. In part 2, 4 features of lymph nodes identified on B-mode sonography--size, shape, border, and echogenicity--and their combinations were evaluated for their ability to diagnose lymph node metastasis. Discriminant and receiver operating characteristic curve analyses were performed. In part 1, B-mode sonography performed in vitro detected 79 (48%) of the 165 histopathologically identified lymph nodes and 34 (87%) of the 39 histopathologically identified metastatic nodes. The mean size, or mean longest axis (+/- standard deviation), of the sonographically detected nodes (6.4 +/- 2.9 mm) was significantly larger than that of undetected nodes (3.6 +/- 1.7 mm; p < 0.01). In part 2, the most effective feature distinguishing metastatic from nonmetastatic lymph nodes was echogenicity, followed by size, shape, and border. However, a combination of at least 2 features (eg, echogenicity and size) provided better distinction of nodes than did any 1 feature. In the receiver operating characteristic curve of the 4-feature combination, an increase in sensitivity is accompanied by a decrease in specificity: at a sensitivity of 100%, specificities decreased to 60% or less. However, even with the optimal combination of features, the sensitivity and specificity did not both reach 85% at any operating point. The results of this node-by-node in vitro study show the current limitations and potential of sonography for assessing colorectal lymph nodes. High-frequency sonography may be insufficient for identifying lymph node metastasis in colorectal cancer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.