A Multi-Beam Optical Stress Sensor (MOSS) provides a contact-free, in-situ platform to measure thin film stress based on the curvature of a bilayer sample. Originally, this instrument was used to measure thin film stress during deposition. However, when combined with a specially designed chemical reactor, it can be used to measure the oxygen surface exchange coefficient of thin film materials [1,2, 3]. In this work, the oxygen exchange coefficient (kchem), stress, biaxial modulus, thermal expansion coefficient (CTE) and chemical expansion coefficient (CCE) were measured as a function of temperature via the wafer curvature technique. Phase pure Pr0.1Ce0.9O1.95 (PCO) powder was prepared through glycine nitrate combustion and subsequent calcination at 1100oC in air. This powder was then pressed in a stainless steel die and fired to 1450oC to produce a pulsed laser deposition (PLD target). In preparation for PLD, (001) oriented 9.5% yttria doped zirconia (YSZ) and (001) oriented magnesium oxide (MgO) substrates (Crystec, GmbH) were pre-annealed at 1450oC for 20 hours to remove residual stress within them. PCO PLD was then conducted at 680oC for 30 min, with a 10-5 torr oxygen partial pressure. After deposition, the PCO bilayers were re-equilibrated with air by firing them in air at 1000oC for 1 hour. To measure kchem, a solution of Fick’s second law was fit to the bilayer curvature response of PCO|YSZ samples responding to abrupt oxygen partial pressure changes (0.21 – 0.021), as shown in Fig. 1 (a). Then the data was fitted to to get kchem values. To measure the biaxial modulus, CTE and CCE, curvature values for PCO|YSZ and PCO|MgO were measured from 25oC to 700oC with a 0.5oC/min ramping rate, converted to stress using Stoney’s equation, and determined using the dual substrate method [4]. As shown in Fig. 1 (b), the PCO thin film kchem values measured here were comparable with other literature PCO thin film kchem values measured using electrode-free techniques such optical relaxation [5, 6]. However, the PCO kchem values measured here were 1-2 orders lower than those measured via impedance spectroscopy (which uses electrodes) [5, 7, 8]. Additional experiments to measure the PCO biaxial modulus, CTE and CCE are underway. Acknowledgements This material is based upon work supported by the Department of Energy under Award Number DE-FE0023315.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.