Abstract

AbstractIn etch plasmas used for semiconductor processing, concentrations of the precursor gas NF3 and of the etch product SiF4 are measured online and in situ using a new diagnostic arrangement, the Q‐MACS Etch system, which is based on quantum cascade laser absorption spectroscopy (QCLAS). In addition, the etch rates of SiO2 layers and of the silicon wafer are monitored including plasma‐etching endpoint detection. For this purpose the Q‐MACS Etch system is working as an interferometer arrangement. The experiments are performed in an industrial, dual‐frequency, capacitively coupled, magnetically enhanced, reactive ion etcher (MERIE), which is a plasma reactor developed for dynamic random access memory (DRAM) technologies. In the spectral range 1028 ± 0.3 cm–1, the absorption cross‐sections of SiF4 and NF3 are determined to be σ = (7.7 ± 0.7) × 10–18 cm2 molecule–1 and σ = (8.7 ± 0.8) × 10–20 cm2 molecule–1, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.