Abstract

A new multi-channel laser-induced fluorescence (LIF) probe with novel optical fiber probe geometry has been designed and integrated into a cone penetrometer testing (CPT) system for in situ contamination detection. The system is capable of collecting excitation and emission matrices (EEMs) of subsurface contaminants as a function of depth in seconds. Compared to our previous multi-channel LIF–CPT system, the new system is faster and more compact, with reduced probe size and sampling area. This article describes the first field demonstration of the system at Hanscom Air Force Base, Massachusetts. One contaminated site within the base was characterized through in situ measurements of 26 LIF–CPT pushes. To validate the LIF results, core samples taken at five locations were analyzed by both on-site LIF measurements and by off-site laboratory analyses with EPA methods. The comparison of the LIF and laboratory results is presented, along with the results of the in situ measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.