Abstract

This case study investigated PCDF and PCDD emissions from a 65MW waste-to-energy plant to identify why an air pollution control system remodeling to accommodate increased production resulted in increased TEQ concentrations. Pre- and post-filter gases were collected simultaneously in four sample sets with varying filter temperatures and with/without activated carbon injection. Samples were analyzed to determine total PCDF and PCDD concentrations, as well as homologue profiles, and concentrations of individual congeners (some remained co-eluted). The total post filter PCDD concentrations where found to increase while the concentrations of PCDF and 2,3,7,8-substituted congeners declined. An investigation of the individual congener concentrations revealed that the increase of PCDD concentrations were due to a few congeners, suggesting a single formation route. The study also concludes that vital information about the formation could be obtained by not restricting the analysis to just the 2,3,7,8-substituted congeners.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.