Abstract

The present study is a comparative energy and exergy analysis of a Proposed gas turbine cycle (PGTC) with a simple gas turbine cycle (SGTC), maintaining the same rate of fuel supply in both cycles. In the PGTC, the air bottoming cycle is operated by exhaust gases from the topping gas turbine cycle by exchanging heat in the heat exchangers (H.E.s) by controlling the path of exhaust gases and compressed air through the bypass control valves. The bypass valve in the topping, as well as the bottoming cycle, direct the combustible product from the combustion chamber to the H.E., in such a way that it optimizes the performance of the proposed combined cycle as compared to SGTC. The results show that the maximum increase in Work net output and thermal efficiency in PGTC compared to SGTC is 65.7% at rp = 4 and turbine inlet temperature (TIT) = 1500 K, whereas the exergy loss by the exhaust gases in the PGTC is much less than the exergy loss by the exhaust gases in the SGTC. The maximum difference in the exergy loss by the exhaust gases in PGTC and SGTC is also observed at rp = 4 and TIT = 1500 K.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.