Abstract

Modifications are examined to increase coal-fired steam power plant efficiency by reducing irreversibilities in the steam generator, including decreasing the fraction of excess combustion air, and/or the stack-gas temperature. Overall-plant energy and exergy efficiencies both increase by 1.4% when the fraction of excess combustion air decreases from 0.4 to 0.15, and by 3.5% when the stack-gas temperature decreases from 149?C to 87?C. When both decreases occur, plant energy and exergy efficiencies both increase by 4.1%. If theoretical combustion air is used, the plant energy and exergy efficiencies both increase by 4.7% when the stack-gas temperature is 87?C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.