Abstract

The objective of this project was to increase the phosphorus (P) retention capacity of a conventional septic tank by adding a recirculating slag filter. Two recirculation modes and recirculation ratios from 5 to 50% were tested in the laboratory with reconstituted domestic wastewater. The best system was recirculation from the end to the inlet of the second compartment of a septic tank with a 50% recirculation ratio in the slag filter, achieving 4.2 and 1.9 mg P/L at the effluent for total phosphorus (TP) and orthophosphate (o-PO4), respectively, and a pH of 8.8. The calculated size of the slag filter for a two-bedroom house application was 1,875 kg for an expected lifetime of 2 years. The 1 mg P/L level goal was not reached, but P precipitation may be favoured by the relatively high effluent pH reaching the infiltration bed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.