Abstract

Low umbilical artery pH is a marker for neonatal acidosis and is associated with an increased risk for neonatal complications. The phase-rectified signal averaging (PRSA) features have demonstrated superior discriminatory or diagnostic ability and good interpretability in many biomedical applications including fetal heart rate analysis. However, the performance of PRSA method is sensitive to values of the selected parameters which are usually either chosen based on a grid search or empirically in the literature. In this paper, we examine PRSA method through the lens of dynamical systems theory and reveal the intrinsic connection between state space reconstruction and PRSA. From this perspective, we then introduce a new feature that can better characterize dynamical systems comparing with PRSA. Our experimental results on an open-access intrapartum Cardiotocography database demonstrate that the proposed feature outperforms state-of-the-art PRSA features in pH-based fetal heart rate analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.