Abstract

In the present study, a numerical investigation was conducted to enhance the film cooling efficiency by using anti-vortex designs. Four configurations are considered in this paper, which are the configuration with the streamwise cylindrical injection, the case with an upstream Barchan dune shape ramp (BDSR), the case with sister holes and the configuration that combine the Barchan dune shape with sister holes. The effects of a blowing ration (M = 0.5, 0.85, 1.0 and 1.5) on the film cooling effectiveness are considered. The validation shows good agreement and almost all flow structures are well reproduced by the RANS computation. Results show that the Barchan dune shapes with sister holes have an influence on thermal and flow structures, this configuration substantially augments the film cooling efficiency.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.