The cut tobacco in the rotational table in vibrating feeder in a pneumatic feeding system is liable to be segregated because of vibration,which results in longer suction time and negatively affects the consistence of cigarette quality. Therefore,the feeder's suction inlet was improved:1) replacing the fixed suction inlet with a suspensible suction inlet; 2) removing the speed reducing motor from the vibrating system to disable the vibration function of the rotational table. After improving,the problem of cut tobacco segregation was well solved,the coefficient of variance of short strands proportion in feeding airlock reduced by 0.23; suction time shortened by 13s; tobacco loss from cigarette end decreased by 2.41 mg/cig. standard deviations of pressure drop and cigarette weight dropped by 51.2 Pa and 5.5 mg/cig. respectively. The test results showed that the structure of cut tobacco pneumatically fed to the cigarette maker was more uniform and cigarette quality was more consistent.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.