Abstract
The matrix converter (MxC) is an ac-to-ac conversion device that can generate variable frequency and variable voltage output. The nine bidirectional switches of an MxC allow pulse-width modulation (PWM) control of input currents and output voltages. PWM switches need "switch commutations" from one switch to another. During these switch commutations, however, unwanted voltage error occurs like a dead time effect in a voltage source inverter (VSI). When PWM pulse-widths are narrower than the time for completing a commutation sequence, voltage error rapidly increases. In the low-speed range, PWM pulses become narrower and voltage distortions become larger due to incomplete commutations. Moreover, these errors are critical in the low-speed operation because the system is sensitive to the smallest voltage error. In this paper, a new PWM strategy is proposed for improving voltage control performance in the low-speed range. Based on the input and output voltage information, PWM pulse-widths are controlled to avoid incomplete commutation. The feasibility of the proposed method is proved through simulation and experimental results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.