Abstract

This paper presents a set of experimental investigations related to the dynamic behavior of supercapacitors (SCs). The experimentally observed results are then used as inputs for the development of an improved version of one of the most common SC RC-equivalent circuit models. The key improvement concerns the accurate modeling of the diffusion phenomenon of the SC residual charge during charging/discharging and rest phases. The experimental procedure needed for evaluating the parameters of the proposed model is also given. The accuracy of the obtained model is then experimentally validated for different cycles characterized by different dynamics.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.