Test methods for the measurement of autogenous shrinkage of cement paste were reviewed, and it is found that few methods can precisely determine the autogenous shrinkage of cement paste at very early age. Therefore, the corrugated tube method was improved by using non-contact linear variable differential transformer (LVDT) sensor for measuring the autogenous shrinkage of cement paste at very early age. The experimental results show that the transformation ratio of the volume deformation to length change for the designed non-contact system can be as high as 0.97, which gives a significant improvement compared to that for the contact system (0.87). Compared to the contact system, the designed non-contact system also has an improved repeatability: the typical standard deviations reach about 50μm/m and 10μm/m before and after setting, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.