Abstract

A three-channel, highly sensitive, fiber optic device is presented to measure acid concentration in lead-acid batteries during their operation. The refractive index and thereby the concentration of sulfuric acid is measured by a bent, silica glass fiber tip, stripped off its cladding. Sensor heads of the device are small enough to be inserted at different positions in the cell of an ordinary, flooded lead-acid battery. Measuring the concentration of the electrolyte at different depths of the battery cell, acid stratification can be accurately determined. During the test of the instrument, about 0.3 Hz temporal and 0.05 wt % concentration resolutions were achieved while the temperature drift was found to be -0.25 wt %/degrees C.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.