Abstract
The objective is to find an appropriate shape function which can enhance the performance of Extended Digital Image Correlation (X-DIC). This paper presents an improved X-DIC methodology to measure the discontinuous deformation across the crack. After simplifying the shape function of crack tip element based on the linear elastic fracture mechanics, non-rectangular subset is proposed to eliminate the effect of the crack width on the measurement accuracy. Then, the work verifies the performance of improved X-DIC by measuring the deformation of a specimen with a mode I crack. Experimental results show that the proposed method is effective at improving the measurement accuracy and enhancing the computational efficiency of X-DIC. In the end, the thesis provides a practical application of improved X-DIC to crack tip deformation measurement.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.