Abstract
The objective of the study was to optimize the accuracy of the exercise test for predicting the presence of significant angiographic coronary artery disease. A retrospective analysis of stored digital exercise electrocardiographic data on 147 men who had undergone exercise testing and cardiac catheterization was performed. With significant coronary artery disease defined as ≥ 70% stenosis, 95 patients had one or more vessel(s) diseased. None were receiving digoxin, had a myocardial infarction or previous coronary artery bypass graft, or exhibited left bundle branch block, left ventricular hypertrophy, Q waves, or ST depression on their resting electrocardiogram. Analysis was performed using the authors' averaging and measurement software at rest and at each 30 seconds throughout the exercise and recovery in leads II, V 2, and V 5. Discriminant function analysis was used to analyze pretest variables, as well as hemodynamic and electrocardiographic changes and symptoms during exercise. A discriminant function score was developed and compared to other treadmill scores. The setting was a 1,000 bed Veterans Affairs Medical Center (Long Beach, CA). Discriminant function analysis chose age, smoking status, presenting chest pain characteristics, and lead V 5 ST slope in recovery to have independent power for separating those with and without coronary artery disease. A discriminant function score using these four variables was used to form a receiver operating characteristics curve (and derive receiver operating characteristics curve areas) for comparison to other exercise test methods and scores: (discriminant function score = .81; slope 3.5 minutes into recovery in lead V 5 = .73; traditional ST amplitude method = .72; ST60 HR index (amplitude of ST depression 60 ms after the J point/delta heart rate) = .66; traditional ST amplitude/HR index (traditional method/delta heart rate) = .75; Hollenberg score = .68; Hollenberg areas only = .66; and ST integral = .66. Receiver operating characteristics curve analysis revealed a trend for the discriminant function score to be superior to all other measurements and scores. Recovery ST slope in lead V 5 performed as well as or better than all other electrocardiographic criteria or treadmill scores except for the authors' discriminant function score.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.