Abstract

A sensitive assay was developed for the determination of low levels of free (unconjugated) glucocorticoids in human, swine (cortisol and cortisone) and rat urine (corticosterone and 11-dehydrocorticosterone), using solid-phase extraction and HPLC with UV absorbance detection (254 nm). Precise quantitation is allowed by the use of internal standards (dexamethasone for swine urine and Reichstein's substance S for rat urine). This simple method allows the use of small urine samples (less than 2 ml), and is suitable for a wide range of applications in human and animal clinical and physiological studies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.