Abstract

Identification of mesial temporal sclerosis is critical in the evaluation of individuals with temporal lobe epilepsy. Our aim was to assess the performance of FDA-approved software measures of hippocampal volume to identify mesial temporal sclerosis in patients with medically refractory temporal lobe epilepsy compared with the initial clinical interpretation of a neuroradiologist. Preoperative MRIs of 75 consecutive patients who underwent a temporal resection for temporal lobe epilepsy from 2011 to 2016 were retrospectively reviewed, and 71 were analyzed using Neuroreader, a commercially available automated segmentation and volumetric analysis package. Volume measures, including hippocampal volume as a percentage of total intracranial volume and the Neuroreader Index, were calculated. Radiologic interpretations of the MR imaging and pathology from subsequent resections were classified as either mesial temporal sclerosis or other, including normal findings. These measures of hippocampal volume were evaluated by receiver operating characteristic curves on the basis of pathologic confirmation of mesial temporal sclerosis in the resected temporal lobe. Sensitivity and specificity were calculated for each method and compared by means of the McNemar test using the optimal threshold as determined by the Youden J point. Optimized thresholds of hippocampal percentage of a structural volume relative to total intracranial volume (<0.19%) and the Neuroreader Index (≤-3.8) were selected to optimize sensitivity and specificity (89%/71% and 89%/78%, respectively) for the identification of mesial temporal sclerosis in temporal lobe epilepsy compared with the initial clinical interpretation of the neuroradiologist (50% and 87%). Automated measures of hippocampal volume predicted mesial temporal sclerosis more accurately than radiologic interpretation (McNemar test, P < .0001). Commercially available automated segmentation and volume analysis of the hippocampus accurately identifies mesial temporal sclerosis and performs significantly better than the interpretation of the radiologist.

Highlights

  • BACKGROUND AND PURPOSEIdentification of mesial temporal sclerosis is critical in the evaluation of individuals with temporal lobe epilepsy

  • Optimized thresholds of hippocampal percentage of a structural volume relative to total intracranial volume (Ͻ0.19%) and the Neuroreader Index (ՅϪ3.8) were selected to optimize sensitivity and specificity (89%/71% and 89%/78%, respectively) for the identification of mesial temporal sclerosis in temporal lobe epilepsy compared with the initial clinical interpretation of the neuroradiologist (50% and 87%)

  • The presence of a positive MR imaging finding with concordant scalp EEG may be equivalent to more invasive monitoring for the localization of seizure and concordant EEG and MR imaging demonstrating mesial temporal sclerosis (MTS) are considered sufficient to proceed directly to surgical resection.[6]

Read more

Summary

Objectives

Our aim was to assess the performance of FDA-approved software measures of hippocampal volume to identify mesial temporal sclerosis in patients with medically refractory temporal lobe epilepsy compared with the initial clinical interpretation of a neuroradiologist. The purpose of this study was to assess the performance of automated MR imaging– based measures of hippocampal volume to identify MTS in patients with medically refractory temporal lobe epilepsy compared with the interpretation of a neuroradiologist and to establish normative values to validate the method for clinical application

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.