Abstract

Jar tests were conducted using synthetic waters containing model colloids and organics to evaluate the coagulation performance of simple FeCl 3 and polymeric iron chloride (PICl) having various polymer yield. Coagulation of synthetic model waters with PICls of different hydrolysis ratios was compared to simple ferric chloride under varying conditions of pH and model water concentrations. The use of PICls seemed to produce similar reduction in turbidity and TOC when compared with using FeCl 3 as a coagulant under typical range for coagulation; however, treatable region was broadened to lower pHs for coagulation of both model waters. By eliminating the region of restabilization of turbidity at lower pHs, an additional region for coagulation using PICls at pH 5–6 was observed. A conceptual surface charge distribution when using different coagulants was established to explain the restablization observed in this study. The different coagulation behaviors of PICls when compared to simple FeCl 3 are probably due to their larger sizes and bearing lower charge density.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.