Equipment operating in installations endangered by the occurrence of potentially explosive atmospheres have special features designed in order to make them suitable for operations in such areas. Equipment designed for use in potentially explosive atmospheres shall be placed on the EU market considering the provisions of the ATEX Directive 2014/34/EU and the harmonized European standards under this Directive. Even if equipment is placed on the EU market in accordance with ATEX Directive 2014/34/EU provisions, the special characteristics providing protection to explosion can be invalidated in installation design, erection, operation, inspection, maintenance or repairing phases. In order to prevent invalidation of explosion protection characteristics an important accent is placed on training and authorization of personnel involved in design, mounting, operation, inspection, maintenance or repairing of equipment/installations operating in potentially explosive atmospheres.

Highlights

  • Equipment intended to be used in potentially explosive atmospheres shall be designed, constructed and placed on the EU market considering the provisions of the ATEX Directive 2014/34/EU [1]

  • To prevent invalidation of explosion protection characteristics an important role has the training and authorization of personnel involved in design, mounting, operation, inspection, maintenance or repairing of equipment/installations operating in potentially explosive atmospheres

  • From this table one can observe that there was an increase in the specific activities for which the personnel performing specific activities related to equipment/installations operating in potentially explosive atmospheres was authorized

Read more

Summary

Introduction

In all areas of activity, to provide quality products or services, the quality standards (i.e. ISO 9001, ISO 14001 etc.) require the use of qualified and competent human resources [3]. Even if equipment is provided in accordance with ATEX Directive 2014/34/EU provisions, the special characteristics providing protection to explosion can be invalidated during the different stages of an installation (design, erection, operation, inspection, maintenance or repairing) [4, 5].

Methods
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.