Abstract

Purpose: To evaluate probable complications of ArtificialIris implantation with iris-fixated intraocular lens.
 Method: Development of photophobia, glare, and psychological strain during face-to-face communication in a 23-year-old man with a widespread traumatic iris defect terminate to make a decision for performing implantation an ArtificialIris (HumanOptics, Erlangen, Germany) under the remnant iris without removing the patient’s existing Artisan lens.
 Results: Without any intraoperative or postoperative complications, the patient’s visual acuity increased by one line, the endothelial cell loss was comparable with the cell loss associated with standard cataract surgery, and the anterior chamber depth and anterior chamber anatomy did not change. At the final follow-up examination, the mean intraocular pressure (IOP) did not differ from baseline, and we achieved high level of patient satisfaction and subjective vision improvement. We discuss the particular importance of considering the patient’s expectations, the appropriate measurements, ways to perfect color evaluation, and the types of ArtificialIris products.
 Conclusion: The implantation of the ArtificialIris in patients with aphakic iris-supported lenses (i.e., preexisting Artisan lenses) is a feasible approach and a useful option for patients with thin irises and iris hypoplasia who are at risk of subluxation or the dislocation of the PCIOL as well as those with sclerally fixed PCIOLs.

Highlights

  • Symptoms such as aberration disorders, contrast sensitivity restriction, dysphotopsia, depth of focus limitations, and ghosting phenomenon experiences can occur in eyes with normal irises; these adverse effects are noticeable in patients with iris and pupilImplantation of ArtificialIris defects

  • In addition to congenital aniridia, which can entail amblyopia,[3] large iris defects and persistent mydriasis after ocular trauma are among the major indications for surgical interventions

  • To best of our knowledge, this study is the first report of an ArtificialIris (HumanOptics) implantation in a trauma patient with an Artisan® lens using a new method

Read more

Summary

Introduction

Symptoms such as aberration disorders, contrast sensitivity restriction, dysphotopsia, depth of focus limitations, and ghosting phenomenon experiences (which can be remembered by: AbCDefGh*) can occur in eyes with normal irises; these adverse effects are noticeable in patients with iris and pupilImplantation of ArtificialIris defects.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.