Abstract
Single event multiple-cell upsets (MCU) increase sharply with the semiconductor devices scaling. The impacts of several test factors on heavy ion single event MCU in 65 nm SRAM are studied based on the buildup of MCU test data acquiring and processing technique, including the heavy ion LET, the tilt angle, the device orientation, the test pattern and the supply voltage; the MCU physical bitmaps are extracted correspondingly. The dependencies of parameters such as the MCU percentage, MCU mean and topological pattern on these factors are summarized and analyzed. This work is meaningful for developing a more reasonable single event test method and assessing the effectiveness of anti-MCU strategies on nanometer-scale devices.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.