Abstract

In previous work, we described and validated a method of scatter correction for singles-mode transmission data using experimental preinjection data acquired with a dedicated rodent PET scanner. In the current work, we investigated the impact that our method has on the quantitative accuracy of small-animal PET. This investigation had 3 stages. We first confirmed the general validity of our method by applying it to preinjection transmission data from a different imaging system (a larger dedicated primate scanner). For these data, we evaluated the accuracy of the reconstructed distributions of linear attenuation coefficients (mu-values). In the second stage, we applied our attenuation-map reconstruction and scatter correction procedure for postinjection transmission data acquired with the dedicated rodent scanner. For these studies, we investigated the quantitative accuracy of reconstructed emission images that use attenuation correction derived from postinjection transmission data. In the third stage, we compared our scatter correction method with 2 more commonly used alternatives (automated rescaling and segmentation of the attenuation-map images). For the primate scanner data, the average reconstructed mu-values with scatter correction were within 3% of the expected values for water and soft tissue, whereas uncorrected values were 19%-26% lower than their expected values. For the postinjection transmission studies, we found that the correct average mu-values and reconstructed activity concentrations consistent with well-counter measurements were obtained only when scatter correction and emission contamination correction were applied to the transmission data. We also found that our transmission scatter correction provides more accurate mu-values and better image quantification than either rescaling or segmentation. Using different imaging systems (primate and rodent) and different scanning protocols (before and after injection), we found that our transmission scatter correction is more accurate (for both reconstructed mu-values and activity concentrations) than the existing alternatives.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.