Abstract

The administration of therapeutic proteins often induces immunogenic response and thus formation of anti-drug antibodies (ADA), which can neutralize the drug’s therapeutic effect and may even cause serious health problems. We here report on the employment of the ultra-sensitive immuno-PCR (IPCR) method to facilitate immunogenicity testing using two established assay formats. In a “bridging assay”, in which ADA forms a bridge to immobilize a signal-generating drug reporter probe, IPCR detection enabled an at least 1000-fold increase in sensitivity, as compared to the analogous ELISA, along with a high drug tolerance value. Moreover, we demonstrate that interfering effects of the biological matrix can be omitted by a simple dilution of analytical samples without loss in assay performance. In a cell-free “neutralizing assay”, in which a labeled drug reporter probe competes for binding to either surface-bound receptors or neutralizing ADA, the IPCR assay also revealed high sensitivity. These results suggest that IPCR has the potential to become a standard methodology in immunogenicity testing.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.