Electrostatic discharge is a familiar interfere. Repeatability of discharge current is poor. Transmission line pulse (TLP) is used in study of immunity of a microcontroller. A TLP generator is first manufactured with the rise time of output pulse less than 1ns. Then couplings by electric field probe, magnetic field probe and direct injection are presented. And immunity test of a microcontroller is done by using the TLP generator and probes. Results show that the tested microcontroller is more sensitive to magnetic field interference; reset pin and crystal oscillator pin of the chip are more sensitive than other pins under action of direct injection interference.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.