Abstract

PurposeTo evaluate and report volumetric dose specification of clinical target volume (CTV) and organs at risk with three-dimensional CT-based brachytherapy. In this study, we analyzed CTV volumes and correlated the dose specification from CT-based volumes with doses at classical point A and International Commission on Radiation Units and Measurements (ICRU) points. Methods and MaterialsTen patients who underwent definitive high-dose-rate brachytherapy for cervical cancer between May 2006 and March 2007 were retrospectively identified for this study. Each patient underwent five intracavitary insertions with CT-compatible ring and tandem applicators using a universal cervical Smit sleeve. Dose of 6.0Gy per fraction was prescribed to the 100% isodose line. The dose distribution was modified using the feature of “geometry optimization” to achieve maximum CTV coverage and to spare the organs at risk. The minimal doses for most irradiated 2, 1, 0.1cm3 of bladder (DBV2 , DBV1, and DBV0.1) and rectum (DRV2, DRV1, and DRV0.1) were determined from dose–volume histograms and were compared with the doses estimated at the ICRU reference points. ResultsThe mean CTV of the 10 patients had a shrinkage trend over the five fractions, with a mean of 77.4cm3 from the first fractions and a mean of 65.5cm3 from the last fractions (r=−0.911, p=0.031). CTV volumes directly correlated with dose to point A (r=0.785, p=0.007). Eight of 10 patients achieved an average dose received by at least 90% of volume (D90) ≥6.0Gy. For bladder, the doses determined from the 3-dimensional (3D) plan correlated significantly with the doses to the ICRU reference bladder point, for example, DBV2 (r=0.668, p<0.001), DBV1 (r=0.666, p<0.001), and DBV0.1 (r=0.655, p<0.001). However, for rectum, the estimated doses to the ICRU reference rectal point did not correlate significantly with doses determined from 3D plan, for example, DRV2 (r=0.251, p=0.079), DRV1 (r=0.279, p=0.049), and DBV0.1 (r=0.282, p=0.047). ConclusionsOur experience showed that excellent dose coverage of CTV can be achieved with image-guided CT-based planning with geometric optimization although maximal sparing of rectum was not achieved. Careful dose constraints and standardization of D90 should be considered when optimizing doses to target tissues such that normal tissue constraints can be met.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.