Abstract

Due to random motion of fetuses and maternal respirations, image quality of fetal brain MRIs varies considerably. To address this issue, visual inspection of the images is performed during acquisition phase and after 3D-reconstruction, and the images are re-acquired if they are deemed to be of insufficient quality. However, this process is time-consuming and subjective. Multi-instance (MI) deep learning methods (DLMs) may perform this task automatically. To propose an MI count-based DLM (MI-CB-DLM), an MI vote-based DLM (MI-VB-DLM), and an MI feature-embedding DLM (MI-FE-DLM) for automatic assessment of 3D fetal-brain MR image quality. To quantify influence of fetal gestational age (GA) on DLM performance. Retrospective. Two hundred and seventy-one MR exams from 211 fetuses (mean GA ± SD=30.9 ± 5.5 weeks). T2 -weighted single-shot fast spin-echo acquired at 1.5 T. The T2 -weighted images were reconstructed in 3D. Then, two fetal neuroradiologists, a clinical neuroscientist, and a fetal MRI technician independently labeled the reconstructed images as 1 or 0 based on image quality (1=high; 0=low). These labels were fused and served as ground truth. The proposed DLMs were trained and evaluated using three repeated 10-fold cross-validations (training and validation sets of 244 and 27 scans). To quantify GA influence, this variable was included as an input of the DLMs. DLM performance was evaluated using precision, recall, F-score, accuracy, and AUC values. Precision, recall, F-score, accuracy, and AUC averaged over the three cross validations were 0.85 ± 0.01, 0.85 ± 0.01, 0.85 ± 0.01, 0.85 ± 0.01, 0.93 ± 0.01, for MI-CB-DLM (without GA); 0.75 ± 0.03, 0.75 ± 0.03, 0.75 ± 0.03, 0.75 ± 0.03, 0.81 ± 0.03, for MI-VB-DLM (without GA); 0.81 ± 0.01, 0.81 ± 0.01, 0.81 ± 0.01, 0.81 ± 0.01, 0.89 ± 0.01, for MI-FE-DLM (without GA); and 0.86 ± 0.01, 0.86 ± 0.01, 0.86 ± 0.01, 0.86 ± 0.01, 0.93 ± 0.01, for MI-CB-DLM with GA. MI-CB-DLM performed better than other DLMs. Including GA as an input of MI-CB-DLM improved its performance. MI-CB-DLM may potentially be used to objectively and rapidly assess fetal MR image quality. 4 TECHNICAL EFFICACY: Stage 3.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.