Abstract

BackgroundThe recent implementation of the dual energy technology on CT-scanners has opened new perspectives in tissue and material characterization. This study aims to evaluate whether dual energy CT can be used to assess the concentration of cocaine of intra-intestinal illegal packets.MethodsThe study was approved by the institutional review board of our institution (CER 13_027_R). From November 2010 to May 2013, all consecutive conveyors in whom a low-dose abdominal CT (LDCT) revealed the presence of illegal intra-corporeal drug packets underwent a dual energy CT series (gemstone spectral imaging) targeted on one container. The mean radiological density (HU) of these packets was measured on the LDCT series, and on the monochromatic dual energy series, at 40 and 140 keV. The difference between the HU at 40 and 140 keV was reported as ∆HU. The effective atomic number Z(eff) was also measured on the monochromatic series. A chemical analysis was performed after expulsion to select cocaine containing packets, and to determine their cocaine concentrations. A correlation analysis was performed between HU, ∆HU and Z(eff), with regard to the percentage of cocaine.ResultsFifty-four cocaine conveyors were included. The mean cocaine content of the packets was 36.8 % (range 11.2–80, SD 15.4), the mean radiologic density 105 HU, the mean Z(eff) 8.7 and the mean ∆HU 163. The cocaine content was correlated with the ∆HU (0.57, p < 0.001), with the Z(eff) (r = 0.56, p < 0.001) but not with radiologic density (r = 0.25, p = 0.064). ∆HU >200 was 0.9 (9 of 10) sensitive and 0.82 (36 of 44) specific to predict a cocaine concentration higher than 50 %.ConclusionMeasuring ∆HU or Z(eff) on dual energy monochromatic CT series can be used to detect ingested packets with cocaine concentration >50 %.

Highlights

  • The recent implementation of the dual energy technology on CT-scanners has opened new perspectives in tissue and material characterization

  • Recent in vitro series have suggested that dual energy CT technology (DECT) may be used to differentiate heroin from cocaine in illegal intra-corporeal packets, swallowed by drug smugglers [8, 9], but no studies were performed while packets were still in the gastro-intestinal tract

  • The aim of the current study is to evaluate whether dual energy CT can be used to assess the concentration of cocaine of intra-intestinal illegal packets

Read more

Summary

Introduction

The recent implementation of the dual energy technology on CT-scanners has opened new perspectives in tissue and material characterization. Once body packets have been identified, a follow-up LDCT gives useful information for the detection of potential complications up to the complete evacuation of the packets, such as the absence of progression of a packet through the gastrointestinal tract, increasing the risk of packet rupture [6]. Recent in vitro series have suggested that dual energy CT technology (DECT) may be used to differentiate heroin from cocaine in illegal intra-corporeal packets, swallowed by drug smugglers [8, 9], but no studies were performed while packets were still in the gastro-intestinal tract. In this setting, knowing the concentration of cocaine contained in the packets may be of great interest for the clinician in charge of the drug conveyer to adapt the therapeutic management in case of impeding rupture

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.